Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm

Yadollahi, Asal and Moeinipour, Aliasghar and Hoseinikhah, Hamid and Ramezani, Javad (2018) Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm. Journal of Cardio-Thoracic Medicine, 6 (3). pp. 355-359.

[img] Text
JCTM_Volume 6_Issue 3_Pages 355-359.pdf

Download (1MB)
Official URL: http://jctm.mums.ac.ir/article_11370.html

Abstract

We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.

Item Type: Article
Subjects: WG Cardiovascular System
Divisions: Journals > J Cardio-Thoracic Medicine
Depositing User: jctm jctm
Date Deposited: 12 Sep 2018 03:34
Last Modified: 12 Sep 2018 03:34
URI: http://eprints.mums.ac.ir/id/eprint/10254

Actions (login required)