Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

Matsutomo, Norikazu and Nagaki, Akio and Sasaki, Masayuki (2014) Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT. Asia Oceania Journal of Nuclear Medicine and Biology, 2 (2). pp. 111-119.

[img]
Preview
Text
AOJNMB_Volume 2_Issue 2_Pages 111-119.pdf

Download (1MB) | Preview
Official URL: http://aojnmb.mums.ac.ir/article_3037.html

Abstract

 Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between conventional and IQSPECT in patients with coronary artery disease (CAD). Methods: Fifty-three patients undergoing rest-gated MPI for the evaluation of known or suspected coronary artery disease were enrolled in this study. In each patient, conventional SPECT (99mTc-tetrofosmin, 9.6 min; 201Tl, 12.9 min) was performed, immediately followed by IQSPECT, using a short acquisition time (4.3 min for 99mTc-tetrofosmin and 6.2 min for 201Tl). A quantitative analysis was performed on an MPI polar map using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function, including the end-diastolic volume, end-systolic volume and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. Results: The segmental percent uptake exhibited a significant correlation between IQSPECT and conventional SPECT (P<0.05). The mean differences in 99mTcâ��tetrofosmin studies were 1.1±6.6 (apex), 2.8±5.7 (anterior wall), 2.9±6.2 (septal wall),4.9±6.7 (lateral wall), and 1.8±5.6 (inferior wall). Meanwhile, regarding the 201Tlâ��SPECT studies, these values were 1.6±6.9, 2.0±6.6, 2.1±5.9, 3.3±7.2, and 2.4±5.8, respectively. Although the mean LVEF in IQâ��SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8 and IQSPECT=68.3±12.1 for 99mTcâ��tetrofosmin; conventional SPECT= 56.0±11.7 and IQSPECT=61.5±12.2 for 201Tl), quantitative parameters were not significantly different between IQâ��SPECT and conventional SPECT.  Conclusion: According to the 99mTcâ��tetrofosmin and 201Tl protocols, IQâ��SPECT images were comparable to and in agreement with conventional SPECT images. Our results suggest that IQâ��SPECT is a useful technology for MPI SPECT, and can lead to an increase in scan efficiency and patient comfort. Â

Item Type: Article
Subjects: WN Radiology . Diagnostic Imaging
Divisions: Journals > Asia Oceania J Nuclear Medicine & Biology
Depositing User: AOJNMB AOJNMB
Date Deposited: 19 Sep 2017 13:58
Last Modified: 19 Sep 2017 13:58
URI: http://eprints.mums.ac.ir/id/eprint/1187

Actions (login required)

View Item View Item