Background. The survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably used for patients whose vessels are unsuitable for an autogenous arteriovenous (AV) fistula. The purpose of this study was to compare the patency rate and associated complications using different types of grafts. Methods. This prospective study was conducted on patients who did not have an appropriate vein for arteriovenous fistula from January 2004 through July 2006. They were divided into two groups, sex, age, and basic data matched. Polytetrafluoroethylene (PTFE) and polyurethane (PVAG) were the two types of grafts used in this study. The functionality of the graft was assessed immediately 1 day and 2 weeks after operation. The clinical follow-up was performed each 3 months until 24 months. Results. One-year patency rate was reported to be 64 and 52 in the PTFE and PVAG groups, respectively. There was no significant difference in 1-year (64 versus 52) and 2-year (49 versus 41) patency rate of the PTFE and PVAG grafts used as vascular access. There was also no difference between the numbers of complications reported in the two groups. Conclusion. It could be concluded that either PTFE or PVAG grafts can be used with the same expected outcomes. © 2010 Informa Healthcare.

Item Type: Article
Additional Information: Cited By :9 Export Date: 16 February 2020 CODEN: UJMSA Correspondence Address: Khashayar, P.; Sina Hospital, Tehran 11367-46911, Iran; email: patricia.kh@gmail.com
Uncontrolled Keywords: Hemodialysis polytetrafluoroethylene (PTFE) polyurethane vascular access graft (PVAG) vascular graft politef polyurethan adult aged arteriovenous fistula article blood vessel prosthesis clinical trial controlled clinical trial controlled study female human indwelling catheter instrumentation male methodology middle aged prospective study randomized controlled trial renal replacement therapy treatment outcome vascular patency Catheters, Indwelling Humans Polytetrafluoroethylene Polyurethanes Prospective Studies Renal Dialysis
Subjects: WH Hemic and Lymphatic System
QU Biochemistry
Divisions: Mashhad University of Medical Sciences
Depositing User: mr lib4 lib4
Date Deposited: 01 Mar 2020 04:44
Last Modified: 01 Mar 2020 04:44
URI: http://eprints.mums.ac.ir/id/eprint/13163

Actions (login required)

View Item View Item