Determination of hematologic reference values of neonates in mashhad Iran

Keramati, M. R. and Mohammadzadeh, A. and Farhat, A. S. and Sadeghi, R. (2011) Determination of hematologic reference values of neonates in mashhad Iran. UHOD - Uluslararasi Hematoloji-Onkoloji Dergisi, 21 (2). pp. 101-105.

[img] Text
Determination of hematologic reference values of neonates in mashhad Iran.pdf

Download (534kB)
[img] Text
224860577_Determination_of_Hematologic_Reference_Values_of_Neonates_in_Mashhad_-_Iran

Download (535kB)

Abstract

The results of laboratory tests have little practical utility unless clinical studies have ascribed various states of health and disease to intervals of values. Several factors affect hematologic values, including race, environment, time of sampling, test method, blood collection site, gestational age and maternal factors. Since these factors vary in various populations, they can cause differences in reference hematologic values. Between September 2007 and March 2008, 447 healthy neonates with more than 2500 g weight were selected and cord blood specimen was taken using EDTA as the anticoagulant. Complete blood count, hemoglobin, hematocrit, and RBC indices were measured by Sysmex cell counter. Differential leukocyte counts were determined in peripheral blood smear. Data were analyzed by SPSS software (version 11.50). A p value < 0.05 was considered to be significant. Mean values and reference ranges of hematologic parameters were as follows: WBC (x103μl)= 11.62 (5.16-18.2), RBC (x106 μl)= 4.45 (3.61-5.29), Hb (g/dl)=15.9 (13-18.8), Hct ()= 48.3 (39.6-56.9), MCV (fl)= 108.7 (97.5-119.8), MCH (pg)= 35.8 (31.7-40), MCHC (g/dl)= 33 (30.1- 35.2), RDW ()= 17.1 (14.1-20.3). We observed some differences in hematologic values of neotanal cord blood in comparison with other references which are in use in daily clinical practice. Especially RBCs and hemoglobin were higher and MCV, WBC and absolute neutrophil count were lower.

Item Type: Article
Additional Information: Export Date: 16 February 2020 Correspondence Address: Mohammadzadeh, A.; Neonatal Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; email: Mohamadzadeha@mums.ac.ir
Uncontrolled Keywords: Hematologic reference values Hematology Neonate Reference range edetic acid hemoglobin article blood cell count blood examination blood sampling blood smear cell count clinical practice computer program erythrocyte female gestational age hematocrit hematological parameters human Iran laboratory test leukocyte leukocyte differential count neutrophil count newborn normal human race reference value umbilical cord blood
Subjects: WH Hemic and Lymphatic System
WS Pediatrics
Divisions: Mashhad University of Medical Sciences
Depositing User: mr lib7 lib7
Date Deposited: 23 Apr 2020 08:30
Last Modified: 23 Apr 2020 08:30
URI: http://eprints.mums.ac.ir/id/eprint/17032

Actions (login required)

View Item View Item