Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Younessi Heravi, Mohamad Amin and Khalilzadeh, Mohamad Ali (2014) Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals. Iranian Journal of Medical Physics, 11 (1). pp. 215-223.

[img]
Preview
Text
IJMP_Volume 11_Issue 1_Pages 215-223.pdf

Download (475kB) | Preview
Official URL: http://ijmp.mums.ac.ir/article_2632.html

Abstract

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and Methods To measure blood pressure changes, two infrared optical transmitters were used at the distances of 5 mm to the receivers. Output of the optical receivers was inserted in analog circuits. PTT was defined as the time between the two peaks of pulse signals by the software. Signals were measured continuously through a serial network communication. An external personal computer monitored measured waveforms in real time. BP was related to PTT and the relationship coefficients were calculated at different physical activities. After determining the linear correlation coefficients for each individual, blood pressure was measured by the cuff and the PTT method and the results were compared. Results PTT computed between the two peaks of wave pulses was strongly correlated with systolic blood pressure (R=0.88±0.034) and the diastolic blood pressure (R=0.82±0.058). Systolic blood pressure (SBP) was measured more accurately than the diastolic blood pressure (DBP). The results of SBP showed that the maximum difference and the error percentages between the cuff method and the present method were 7.98±2.88 and 6.33±2.51, respectively. Moreover, the maximum difference and the percentage errors between the cuff method and the present method of DBP were 10.13±3.82 and 10.97±3.89, respectively. Conclusion Monitoring blood pressure with the designed system can be recommended as a useful method to indicate cardiovascular diseases and used for personal healthcare purposes. Â

Item Type: Article
Subjects: WN Radiology . Diagnostic Imaging
Divisions: Journals > Iranian J Medical Physics
Depositing User: ijmp ijmp
Date Deposited: 25 Sep 2017 18:25
Last Modified: 25 Sep 2017 18:25
URI: http://eprints.mums.ac.ir/id/eprint/4413

Actions (login required)

View Item View Item